The HP 95000 auto-test contactor is designed for use with the HP 95000 tester and provides 1 GHz performance with less than 1 ns pulse widths for testing direct rambus DRAM. The contacts feature 0.75 mm pitch, 1.3 to 1.6 nH self inductance, 0.02 to 0.09 capacitance and 9.3 GHz bandwidth at 1.0 dB for accurate test results from -55 to 150°C. The contactor uses a proprietary socket design with interchangeable package inserts that allow the contactor to be refigured for different packages by changing the insert.
OZ Technologies Inc.
Hayward, Calif.