New Products
02/01/2001
|
Chamber
Stability and photostability chambers meet WHO and ICH guidelines for general stability testing of new drug substances and products Q1A(R), long-term and accelerated refrigerated testing and photostability testing. With a temperature range of from 5 degrees Celsius to 60 degrees Celsius and humidity control from 20 percent to 98 percent RH, the 10-cubic-foot benchtop and 30-cubic-foot reach-in chambers create a variety of repeatable environmental conditions, according to the manufacturer. Standard features include stainless steel interiors, LED temperature and humidity display, audible and visual temperature alarms and stainless steel wire rod shelves.
Caron
Marietta, OH
(740) 373-6809
|
Glovebox
The 870-CLC closed-loop containment isolator is programmed to maintain a slight negative working pressure (-0.50 in H2O). The internal atmosphere is continually filtered by two HEPA filters. If the internal negative pressure rises above -0.55 in H2O, the programmable logic controller automatically opens the atmosphere supply valve. Incoming gas is automatically filtered through the dual HEPA filters. Once the internal atmosphere reaches the set point, the automatic valve closes. The unit features a manual ball valve for connection to the house exhaust/filter system.
Plas-Labs Inc.
Lansing, MI
(800) 866-7527
Instrumentation manifolds
The VC series of compact instrumentation manifolds includes 2-valve, 3-valve and 5-valve (double bleed) configurations for process measurement and control. The products are available with 1/2 NPT or ISO/R228 process connections and DIN 19213-B3 or MSS SP-99 flange instrument connections. According to the manufacturer, all metal components, including trim, are made of 316 stainless steel for extended corrosion resistance and service life.
Swagelok Company
Solon, OH
(440) 349-5934
|
Pressure alarm
The TS5130 valve controller incorporates a user-programmable low-pressure alarm that sounds an alarm and shuts off the dispensing function when the pressure being applied drops below the preset level. Valve control features include valve purge, valve test, external actuation and end-of-cycle signal. The LED display shows the valve-open time and air-output pressure. The time/pressure button on the control panel enables the operator to toggle the display between valve-open time and valve-open pressure.
Techcon Systems
Garden Grove, CA
(800-776-0440
|
Environmental analyzer
The VOC71M measures low levels of volatile organic compounds, including benzene, toluene, ethylbenzene, xylenes and 1-3 butadiene, in ambient air. Measurement is based on gaseous phase chromatographic separation and detection by a photo-ionization detector or ionization detector. The instrument can operate autonomously or linked to a PC using Winchrom software under Windows.
Altech Environment USA
Geneva, IL
(630) 262-4400
|
Sulfuric acid detector tube
Tube No. 244U direct reading detector tube for airborne levels of sulfuric acid has a measuring range of 0.5 to 5 mg/M3. It can monitor airborne levels of sulfuric acid in the TLV range in less than two minutes. The system includes a piston type volumetric pump for rugged reliability, and it is expandable with direct reading detector tubes available for hundreds of additional applications, according to the manufacturer.
Sensidyne Inc.
Clearwater, FL
(727) 530-3602
|
Water preservative
The water preservative is liquid formulated to inhibit the growth of harmful bacteria in self-contained eyewash stations. One 8-ounce bottle preserves 14 to 16 gallons of water. For smaller self-contained stations the proper amount of preservative is added using the graduated marks printed on each bottle label. Recommended concentration is 0.5 ounce of preservative for every gallon of eyewash.
Fendall
Arlington Heights, IL
(847) 577-7400
Polyurethane/Hypalon glove
The YP-832 series of polyurethane and hypalon glove offers increased puncture, tear and abrasion resistance, thereby offering longer life. Chemical resistance properties such as VHP sterilization are not sacrificed.
Renco Corp.
Manchester, MA
(800) 257-8284
Vacuum-operated tooling
The tooling handles InP wafers and fragments in cleaning and wet processing applications. Available in stainless steel for solvents and plastic for acids and base solutions, this tooling can be installed on either robotic or manual load systems. According to the manufacturer, the spindle processors achieve high-quality, high-yield results on an on-demand basis. A selection of sprays, dispensers, high-performance nozzles and brushes optimizes all processing steps, with all parameters PC controlled using Windows-based software.
Solid State Equipment Corp.
Horsham, PA
(215) 328-0700
|
Hazardous materials kit
The deluxe Hazmat Kit III offers a two-step approach to identifying unknown airborne compounds using detector tubes. The first step utilizes two multi-layered qualitative tubes and a color chart to identify more than 70 compounds in two to three minutes. The second step incorporates an additional 13 detector tubes and a decision-tree style logic chart to further qualify the first step results.
Sensidyne Inc.
Clearwater, FL
(727) 530-3602
|
Dispensing system
The Century 718 SMT is used in the dispensing of surface mount adhesive, solder paste and conductive adhesive in PCB assembly applications. The system is offered in two configurations to service both medium- and high-mix production operations. The first offers the C-718 SMT platform with the non-contact DispenseJet valve, which handles adhesive dispensing throughput of up to 20,000 dots per hour and shoots the adhesive fluid onto the PCB substrate from a uniform height of approximately 1.5 to 2.0 mm above the board. The second configuration features the company's DV-7000 Heli-flow rotary positive displacement pump for solder paste and conductive adhesive dispensing.
Asymtek
Carlsbad, CA
(760) 431-1919
AC Tester
The Activated Carbon (AC) Tester instrument determines the volume of adsorption space in activated carbons. According to the manufacturer, the tester works with used, partially used and impregnated AC. PACS Inc.
Coraopolis, PA
(724) 457-6576
Rubber flooring
The norament and noraplan systems in the nora Rubber Flooring Program 2001 feature new color ranges and designs. The manufacturer's hammered surface option (a non-directional texture) now includes more colors in tiles and color matching one-piece nosing-tread-riser stairtreads. Each system is color coordinated from warm to cool shades and includes earthtones to facilitate specification throughout the applications of a commercial project.
Freudenberg Building Systems
Lawrence, MA
(978) 689-0530
|
Respirator
Respirator and respirator systems come with a MSHA/NIOSH-approved, continuous-flow full mask, half mask or hood style air respirator, an ambient air pump and 50 or 100 feet of breathing air hose. The disposable hoods offer a loose-fitting alternative to masks. One-, two- and three-worker systems are available.
Allegro Industries
Garden Grove, CA
(800) 622-3530
|
Anti-static cello tape
Available in yellow, red or blue and yellow, red or blue with ESD symbols, the cellophane tapes are coated with a high-tack, non-staining natural rubber adhesive system, are 1.8- mil thick and have tensile strength of 24 pounds/in. The static-free tape is easily hand torn. Sizes are 1/2-, 3/4-, 1- and 2-inch widths on 3-inch plastic core.
SPI Westek
Brea, CA
(800) 446-2888
|
Analyzer transmitter
The compact, modular Continuous Emissions Monitoring (CEMS) solution combines the CAT Continuous Analyzer Transmitter with a Sample Handling System (SHS). According to the manufacturer, the reduced size and rugged packaging enables the analyzer system to be mounted close to the process. Local mounting eliminates sample line measurement delays that can contribute to poor analyzer response. The CAT is suitable for high-temperature process, tropical and desert applications with ambient operating temperatures up to 65 degrees Celsius.
Rosemount Analytical
Orville, OH
(330) 684-4479
|
EtO sensor
The gas sensor makes sure that ethylene oxide (EtO) levels in sterilization chambers are high enough. The product continually monitors gas concentrations in the chamber, showing EtO levels over the entire sterilization cycle. The detector can be factory installed on new chambers or retrofitted to an existing cabinet. The unit fits flush against the chamber wall or ceiling. According to the manufacturer, the detector immediately warns of trouble in the unit.
Sensor Electronics Corp.
Minneapolis, MN
(952) 938-9486
Industrial glove
The SemperGuard industrial glove family complies with FDA 21 CFR guidelines and agriculture and agri-foods Canada requirements. The gloves are intended for use in food, food processing, pharmaceutical and laboratory applications.
Sempermed USA Inc.
Palm Harbor, FL
(800) 366-9545
|
Humidifier
The GTS-600 and GTS-800 humidifiers have capacities ranging from 75-600 pounds/ hour. Multiple units can be linked, and indoor or outdoor mounting is offered. The Vapor-Logic3 humidifier controller, which offers full modulation control of the burner section, includes a keypad with menu-driven access to all system functions. The controller supports Echelon's LonTalk interoperability for integration to most building management systems.
Dri-Steem
Eden Prairie,
(612) 949-2415
|
EMI air filters
Dual EMI air filters use conductive silver/copper adhesive caulk that fully bonds EMI mesh to aluminum filter frames to promote enclosure grounding of EMI noise. This is further enhanced by wrapping an EMI nickel/copper metalized fabric around a neoprene foam gasket. Gaskets can be installed around the perimeter of the filter frame for full conductivity of the framed filter to the enclosure in which it is installed. Chromate and irridite finishes are available on aluminum components to provide corrosion protection and improved conductivity.
Universal Air Filter Co.
Sauget, IL
(800) 541-3478
|
Polishing station
The WaterPro PS polishing station delivers up to 1.8 liters/minute of Type I water. Water is dispensed from a gun or a valve on the built-in module. With control panel buttons and LED display the user can program the system to dispense water for a set period of time from 1 to 99 minutes. According to the manufacturer, the unpigmented virgin natural polypropylene bowls have no impurities to contaminate the water, maintaining low TOC levels. The bowls accommodate various combinations of deionization, carbon and organic adsorption filter cartridges based on application requirements.
Labconco Corp.
Kansas City, MO
(816) 333-8811
|
Flow meter
The WA40 series positive displacement flow meter is used to measure volumetric flow of medium and high-viscosity fluids. The units are available in stainless steel or high-strength aluminum, while gears and bearings are all stainless steel construction. According to the manufacturer, the series is rated to 5,000 PSI in flow rates of 0.02 to 2 GPM to 0.5 to 60 GPM. Applications include lubricating oils, high-viscosity fluids, paints and epoxies, polyurethanes, fuels, additives, solvents and chemicals.
FloCat
Kenosha, WI
(262) 653-0790
Laminar flow clean bench
Designed for animal transfer in research laboratories, the EdgeGard animal transfer station delivers ISO Class 5 (Class 100) HEPA-filtered air across the work surface. According to the manufacturer, the high-velocity return air slots ensure a particle-free work surface and protection from contaminated backwash air. The portable unit is available in 4- and 6-foot models.
The Baker Company
Sanford, ME
(800) 992-2537
|
Iris damper
The Iris damper adjusts and measures airflow at one location. It uses interlocking steel plates and a calibrated control level to form an adjustable aperture. Airflow is determined by measuring differential pressure across the pressure ports and referring to the matching performance curve. Ten sizes are available from 4 to 32 inches, with capacities from 15 to 25,000 cfm. They are manufactured of galvanized steel and fitted with a neoprene gasket for airtight mounting.
Continental Fan Manufacturing Inc.
Buffalo, NY
(800) 779-4021
|
Gas pressure manometer
Series 1213 gas pressure manometer uses tap water to provide clear visual indication of natural gas pressure, or that of other compatible gases, up to 15 inches (381 mm) of water column. According to the manufacturer, this "tube in a tube" instrument is constructed of durable plastic and has wetted parts of vinyl, PVC and nylon. Temperature limit is specified as 140 degrees Fahrenheit. Price is $15. A shorter model (7 inches/177.8 mm) is available for gas pressures up to 7 inches w.c. Both models have a magnetic clip to facilitate temporary or permanent mounting.
Dwyer Instrument Inc.
Michigan City, IN
(219) 879-8000
|
Exam glove
The Polymed exam glove utilizes fusion bonding of latex and synthetic polymers to create a multi-layer glove that combines elasticity and strength. According to the manufacturer, the glove contains 50 micrograms or less of total water extractable proteins per gram, which reduces the potential for allergic reactions. A multi-layer coating provides comfort and ease of donning for wet or dry hands. The micro-rough surface on the fingers and palm offers increased sensing and a safe grip. The glove has a 1.5 AQL value and a neutral pH balance.
Sempermed USA Inc.
Palm Harbor, FL
(800) 366-9545